Westinghouse 5X00063G01 | Ovation Analog Input Module 8-Channel

$ 96.54

Categories: ,
Description Product Introduction Process transmitters output 4–20 mA, but if that signal arrives at the controller with noise or offset, your control loop suffers. The 5X0006301 sits in an Ovation I/O rack precisely to prevent that—it’s the front end for pressure, flow, and level transmitters in steam or balance-of-plant applications. Unlike some universal input cards that try to do everything, this module is dedicated to analog current sensing. It handles eight differential inputs at 16-bit resolution. That resolution matters when you’re trying to see a 0.1% change in drum level. Isolation is rated at 1500 VDC channel-to-channel, which in my experience, saves the backplane when a field short occurs.   Key Technical Specifications Parameter Value Model Number 5X00063G01 Manufacturer Westinghouse / Emerson Series Ovation Product Type Analog Input Module Number of Channels 8 (Differential) Input Signal Type 4–20 mA (Standard loop-powered transmitters) Resolution 16-bit Isolation 1500 VDC (Channel-to-channel and channel-to-backplane) Accuracy ±0.1% of span (typical at 25 °C) Update Rate Configurable, typically 50 ms per module scan Backplane Current Draw 500 mA @ 5 VDC (nominal) Field Wiring Removable terminal blocks (included) Certifications CE, UL, CSA (for Class I, Div 2 locations typically)    Firmware / Software Versions & Upgrade Notes This module is hardware-revision dependent for firmware. Before installing a 5X00063G01 into an existing Ovation rack, check the controller’s firmware revision level. Compatibility: Works natively with Ovation 3.0 and later. For v2.x systems, the module will function, but you’ll lose the ability to configure input filtering digitally—you’d have to handle it in the control logic. The G0x Revision: The “G01” suffix is the base revision. Later revisions (G02, G03) added support for HART pass-through. This specific unit (G01) does not pass HART digital data. It reads the analog loop current only. If your plant uses HART for predictive maintenance, you’ll need a newer revision or a separate HART multiplexer. Upgrade Path: There isn’t a field-upgradeable firmware for this module. If you need HART, you swap the card. No driver conflicts to worry about here—the I/O base handles the handshake automatically.    Compatibility & Replacement Matrix If you are swapping this card out or looking for a direct spare, use this guide. Original Model Replacement Model Compatibility Level Key Notes 5X00063G01 5X00063G02 Drop-in (Hardware) G02 adds HART capability. Electrically and mechanically identical. If software doesn’t use HART, it’s a 1:1 swap. 5X00063G01 1C31125G01 Needs Adaptation Different form factor (Legacy I/O). Requires different terminal units (1C31124G01) and possibly a different cable. Verify rack type. 5X00063G01 5X00119G01 Incompatible That is a Discrete Output module. Do not install in an Analog Input slot. 5X00063G01 5X00070G01 Incompatible That is a Thermocouple/RTD Input module. Different signal conditioning. PR6424/001-030 PLC PR6424/002-101 PLCDCS PR6424/003-101 PLC PR6424/019-100 PLC PR6424/019-021 PLC Email: [email protected] Phone: 86 15340683922 Sales:Wu Jiedong Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts. All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager). Our product: brand new original packaging Our warranty: All new or repaired parts have a 12 month warranty period beginning Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed! If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!