WESTINGHOUSE 5X00058G01 Module | Ovation Series I/O Card

$ 96.54

Categories: ,
Description Key Technical Specifications Parameter Specification Part Number 5X00058G01 Product Type Analog Input (AI) Module Series Ovation DCS Channels 16 differential inputs Input Types 4-20 mA, 1-5V DC, 0-10V DC (configurable) Resolution 16-bit A/D conversion Accuracy ±0.1% of span typical Update Rate All channels scanned every 50 ms Isolation Channel-to-channel isolation: none (common ground) Power Supply 5V DC and 24V DC from backplane Mounting Plugs into Ovation I/O rack Indicators Module status LED, channel activity LEDs Condition New Surplus (Factory Sealed) Product Introduction The WESTINGHOUSE 5X00058G01 is a 16-channel analog input module designed for the Ovation distributed control system. It interfaces directly with field transmitters sensing pressure, flow, temperature, and level, converting 4-20 mA signals into digital values for the control logic. This module is the workhorse for process data acquisition in Ovation cabinets worldwide. The 5X00058G01 features 16-bit resolution and fast update rates suitable for closed-loop control applications. This unit is new surplus, factory-sealed in original Westinghouse/Emerson packaging. Ovation components are mission-critical in power plants; contact us for current stock status and firm pricing. Frequently Asked Questions (FAQ) Q: Can I mix 4-20 mA and 1-5V signals on the same 5X00058G01 module? A: Yes, but with a catch. The WESTINGHOUSE 5X00058G01 uses common analog input circuitry. You configure each channel individually via software in the Ovation controller. However, the module doesn’t provide channel-to-channel isolation. If you mix signal types, ensure all transmitters share a common ground reference. Otherwise, you’ll chase ground loop headaches. In power plants, I’ve seen this cause erratic readings on critical loops. Q: Is the 5X00058G01 hot-swappable in a running Ovation system? A: Technically yes, practically… be careful. The Ovation backplane supports live insertion, but the 5X00058G01 draws enough current that you’ll see a momentary glitch on all 16 channels when it seats. If those channels are in critical control loops, expect alarms or bumpy control. My rule: hot-swap only if the module is monitoring non-critical points. For PID loops controlling pumps or dampers, schedule a shutdown. Q: What’s the difference between 5X00058G01 and 5X00058G02? A: The G02 suffix typically indicates a hardware revision with updated component sourcing. Functionally, they’re identical—same 16 channels, same resolution, same firmware behavior. However, never mix revisions in a redundant pair configuration. If you have redundant I/O, both modules must match exactly. Mixing G01 and G02 in redundant slots will cause synchronization faults. Verify your existing revision before ordering. Q: My module shows “Channel Data Invalid” on several inputs. Is the 5X00058G01 dying? A: Not necessarily. That fault often means the module isn’t seeing valid current from the field. Before blaming the WESTINGHOUSE 5X00058G01, check your field wiring. I’ve wasted hours troubleshooting “bad modules” that turned out to be blown fuses in transmitter loop power supplies or loose terminal screws. Put a meter across the input terminals. If you see 4-20 mA and the module still faults, then suspect the hardware. Q: Does this module support HART protocol passthrough? A: No. The 5X00058G01 is a standard analog input module—it reads the raw 4-20 mA signal and nothing else. It does not superimpose or extract HART digital communication. If you need HART configuration capability from the DCS, you need the HART-enabled version (different part number) or a separate HART multiplexer. This module just gives you the analog value. Q: What’s the typical failure mode for these modules in power plant service? A: Honestly, input protection circuitry takes the hit. Surges from lightning strikes near transmission lines or welding on nearby piping can fry the front-end components. The 5X00058G01 has some protection, but it’s not bulletproof. You’ll see one channel die while others work fine—classic sign of surge damage. The module itself is solid; it’s the plant electrical environment that kills them. Always check your grounding before blaming Westinghouse. 80190-560-01-R FCS IC693CPU364 PLC MDS-CH-V2-3535 DCS mkd090b-047-kp1-kn Y-2012-2-H00AA DCS Email: [email protected] Phone: 86 15340683922 Sales:Wu Jiedong Our products are guaranteed for 1 year, with new and original production stopped and imported spare parts. All prices listed on the official website are subject to confirmation by contact: Wu Jiedong (manager). Our product: brand new original packaging Our warranty: All new or repaired parts have a 12 month warranty period beginning Our payment: 100% telegraphic transfer of inventory items before shipment, conditions can be proposed! If you have any downtime spare parts that you cannot find, please feel free to call or use email to contact me. If there are issues that the product cannot solve, please contact me. Product prices can be negotiated. Please do not consider contacting me!